MIPEX-04 ppm [CH4]

Ultra-low power methane sensor for compact gas detectors

MIPEX-04 PPM CH₄ is ​​a high-performance NDIR sensor with 10 ppm resolution, designed to detect methane at low concentrations — from just 50 ppm up to 5% vol.

Presentation in PDF

Contact for details Get an offer

Features

Smart NDIR sensor for portable gas detectors, offering precise methane detection with ultra-low power consumption (less than 100 µA average current)for long-term autonomous use.It allows designing battery operated gas detector lasting more than 12 months without charge
  • ULTRA-LOW POWER CONSUMPTION

    Average power consumption ≤ 0.3 mW
  • INTEGRATED MICROCONTROLLER

    Returns linearized and temperature-compensated digital output via UART interface.
  • TECHNOLOGY

    The simultaneous control of ppm and LEL concentrations. Dual-wavelength LED‑based technology minimizes interference from water vapor and contamination, ensuring high measurement reliability.
  • EXPLOSION PROOF DESIGN

    Intrinsically safe explosion protection level “ia” in compliance with: IECEx, ATEX, UL913, CSA.
  • STANDARDS COMPLIANCE

    Ex ia op is I Ma / Ex ia op is IIC Ga according to IEC 60079-0, IEC 60079-11, IEC 60079-28 -40 ≤ Ta ≤ +60 °C IM 1/II 1 G Ex ia op is I Ma / Ex ia op is IIC Ga according to EN IEC 60079-0, EN 60079-11, EN 60079-28 -40 ≤ Ta ≤ +60 °C C I, Div 1, Gr A,B,C,D; C I, Zone 0, AEx ia op is IIC Ga; Ex ia op is IIC Ga according to UL 913, UL 60079-0, UL 60079-11, UL 60079-28, CSA C22.2 № 60079-0, CSA C22.2 № 60079-11, CSA C22.2 № 60079-28
  • LONG-TERM MEASUREMENT STABILITY OVER 10 YEARS

Key specifications

Key parameters from the product booklet. Full data are in the Documents section below.
Parameter Value
Target gas CH4
Measurement range 0…1000 ppm; 0.1…5.0 % vol.
Resolution / accuracy (+20…+25 °C) 10 ppm resolution; ± 50 ppm or ± 5% of reading (whichever is greater)
Response time T(90) ≤ 22 s
Average current consumption ≤ 100 µA
Average power consumption ≤ 0.3 mW
Supply voltage +2.5…+5.0 V
Operating temperature -40…+60 °C
Operating humidity Up to 98 % (without condensation)
Dimensions 52×24×18 mm
Weight 11.0…13.5 g

How to order

  • Minimum order: from 1 sensor.
  • Lead time: depends on stock availability, typically from 1 to 8 weeks.
  • Samples: free of charge when a project is opened under an agreement on specific conditions; otherwise paid as part of a quotation, or through the MIPEX Evaluation Kit.
  • USA and Canada: order directly from MGS Technology or through Scout Innovations. Other regions: directly or through the distributors listed on the Contacts page.

Request samples Get an offer

Other ultra-low power gas sensing solutions

NDIR Gas Sensors

MIPEX-05 [CH4|C3H8|CO2]

The outstanding ultra-low power consumption of 0.2 mW allows the MIPEX-05 in standard housing to be used effectively in the manufacture of customized portable gas devices and wireless measurement systems for the monitoring of combustible methane, hydrocarbons and CO₂ gases with long battery life. Its power consumption is 10 times lower than that of the previous MIPEX-02 model.

Details

NDIR Gas Sensors

MIPEX-05 ppm [CH4|C3H8]

MIPEX-05 ppm is a high-sensitivity version of an ultra-low power infrared gas sensor in the 4th series housing with 10 ppm resolution for hydrocarbons measurement in ppm and LEL concentrations. Due to low-power consumption and high resolution, it allows battery-powered gas detectors to last years without charge and detect low concentrations.

Details

NDIR Gas Sensors

MIPEX-04 ppm [CH4|C3H8]

MIPEX-04 ppm is a high-performance NDIR sensor with 10 ppm resolution, designed to detect methane and propane at low concentrations. It is intended for automatic continuous monitoring of Threshold Limit Value (TLV) and leaks in industrial applications.

Details

NDIR Gas Sensors

MIPEX-04 [CH4|C3H8]

MIPEX-04 sensors have been developed for use in portable individual detectors and wireless combustible gas monitoring systems. The uniquely low average power consumption of ~ 0.1 mW enables the production of autonomous instruments that do not require recharging and maintenance for up to 24 months.

Details

In field tests

MIPEX-06 [CH4|C3H8|CO2]

MIPEX-06 is an ultra-low power infrared gas sensor in the 4th series housing with standard-pin configuration for portable devices. It is designed for automatic continuous measurement of hydrocarbons and CO₂ concentrations in hazardous areas.

Details

NDIR Gas Sensors

MIPEX-02 [CH4|C3H8|CO2]

Metal housing, wide temperature range, resistance to humidity and dust, optical principle of operation providing long-term reliability in aggressive operating conditions, allows MIPEX sensors to be placed as measuring elements in stationary gas detectors and gas analytical systems.

Details

product in development

MIPEX-1F [CH4|C3H8]

The MIPEX-1F is a ready-to-use optical measuring unit for stationary gas analysis systems. The sensor provides automatic and continuous measurement of hydrocarbon gas concentrations in hazardous area atmospheres, ensuring high accuracy and stability of readings.

Details

product in development

MIPEX-1H [CH4|C3H8|CO2]

The MIPEX-1H is a compact infrared sensor for measuring methane, propane and carbon dioxide concentrations for small and portable gas detectors. The power consumption of only 0.2 mW ensures long autonomous operation of the devices, and the minimal dimensions of 20×20×10 mm allow to significantly reduce the size of the final device.

Details

product in development

MIPEX-01S [CH4|C3H8|CO2]

MIPEX-01S is a compact infrared sensor in a Series 1 housing for automatic continuous measurement of hydrocarbons or CO₂ concentrations in harsh environments. It is designed for small-sized and portable gas detectors.

Details

product in development

MIPEX-01D [CH4&CO2 | C3H8 & CO2]

MIPEX-01D is an ultra-low power NDIR gas sensor intended for automatic continuous measurement of CH₄ & CO₂ or C₃H₈ & CO₂ in atmosphere of hazardous areas. Its compact dimensions of 20×20×10 mm and ability to simultaneously measure the concentrations of two gases allow to significantly reduce the size of the final device.

Details