Features
MIPEX-02 [C₃H₈] is engineered for demanding environments such as oil & gas, mining, and process industries. Its low-power design, robust performance in dusty conditions, and explosion-proof construction make it ideal for integration into wireless and fixed gas detectors.
-
low power consumption
Average power consumption ≤ 2.5 mW.
-
Integrated microcontroller
Returns linearized and temperature-compensated digital output via UART interface.
-
technology
Non-dispersive infrared (NDIR) sensing founded on selective absorption of infrared light, utilizing a dual-wavelength LED-based method to minimize the effects of humidity, dust, and optical contamination.
-
Explosion-proof design
Intrinsically safe explosion protection level “ia” in compliance with: IECEx, ATEX, UL913, CSA.
-
STAndards compliance
I M1 / II 1G Ex ia op is I Ma / Ex ia op is IIC Ga
according to EN IEC 60079-0:2018, EN IEC 60079-11:2012, EN IEC 60079-28:2015
C I, Div1, Gr A,B,C,D;
C I, Zone 0, AEx ia IIC Ga;
Ex ia IIC Ga according to UL 913, CAN/CSA-C22.2 No.157-92
Ex ia op is I Ma / Ex ia op is IIC Ga
according to IEC 60079-0:2017, IEC 60079-11:2011, IEC 60079-28:2015
-
Standart series 4 size
Durable plastic or stainless steel housing ⌀20.3×16.6 mm.
-
LONG-TERM MEASUREMENT STABILITY OVER 10 YEARS